This is a . The system shuts down the lift function to prevent deep discharge of the battery or thermal damage to the lift motor and contactors.
. The tiller head sensor is reporting that it isn't quite at zero, even when your hands are off the controls. Because the safety system can't confirm the truck is in a safe "neutral" state, it locks out functions to prevent the machine from creeping or moving unexpectedly. How the Story Ends (Troubleshooting) jungheinrich eje 120 error code 4372 work
The contactor that sends power from the battery to the lift pump motor can have pitted or welded contacts. A high-resistance contactor will pass enough voltage for diagnostics, but under load (lifting), the voltage collapses. This is a
Troubleshooting Jungheinrich EJE 120 Error Code 4372 Error code on a Jungheinrich EJE 120 typically points to an analogue implausible signal from the tiller head sensor . This error often manifests by disabling the truck's hydraulics while sometimes allowing other functions to continue. It is a known issue that frequently occurs when the control system cannot find a clear "neutral" or zero-travel position for the drive or lift/lower controls. Primary Causes of Error 4372 The tiller head sensor is reporting that it
: Potential issues with the internal card or sensor within the tiller head unit.